Home ProductsSwitching Power Supply Adapter

200 - 260V AC 200W Switching Mode Power Supply CE RoHS Approved

200 - 260V AC 200W Switching Mode Power Supply CE RoHS Approved

  • 200 - 260V AC 200W Switching Mode Power Supply CE RoHS Approved
  • 200 - 260V AC 200W Switching Mode Power Supply CE RoHS Approved
  • 200 - 260V AC 200W Switching Mode Power Supply CE RoHS Approved
200 - 260V AC 200W Switching Mode Power Supply CE RoHS Approved
Product Details:
Place of Origin: Guangdong, China (Mainland)
Brand Name: e.mini
Certification: CE/RoHS
Model Number: LR-200W
Payment & Shipping Terms:
Minimum Order Quantity: 40 Pieces
Packaging Details: Work Bin and Handle Box
Delivery Time: Within 2-7 working days after getting deposit
Payment Terms: T/T, Western Union, Paypal
Supply Ability: 25000 Pieces per Month
Contact Now
Detailed Product Description
AC Input: Max. UnitVin(230vac) 200 230 264 VACrms DC Output: +3.3V,+5V,+12V,-12V,+5Vsb
Production Name: Switching Mode Power Supply Protection: Over Current Protection,over-voltage Protection,thermal Protection, Short-circuit Protection
Frequency: 47 - 53 Hz
High Light:

switched mode power supply

,

switch mode power supply

 

200 - 260V AC 200W Switching Mode Power Supply CE RoHS Approved 

 

CE RoHS Approved Switch Power Supply, Switching Mode Power Supply Realan LR-200W 

 

Specifications

 

1.thermal protection

2.over current protection
3.over-voltage protection
4.short-circuit protection

 

 

Realan Switch Power LR-200W

 

 

1.1 AC input

 

Table 1 list AC input voltage and frequency requirements for continuous operation. The power supply shall be capable of supplying full-rated output power input voltage ranges rated 200-260VAC rms nominal. The power supply shall automatically recover from AC power loss .The power supply must be able to start up under peak loading at 200VAC.

Table 1: AC input Line Requirements

Parameter Min. Nom. (1) Max. UnitVin(230vac) 200 230 264 VACrms

Frequency 47 - 53 Hz Iin (230VAC) 3 Arms

 

1.1.1

Input Overcurrent Protection,The power supply shall incorporate primary fusing for input overcurrent protection ,Fuses should be slow-blow type or equivalent to prevent nuisance trips.

 

1.1.2 Inrush Current Limiting

100A Max. At 25℃ Cold Start

 

 

1.2 DC Output

 

Voltage

+3.3V

+5V

+12V

-12V

+5Vsb

 

MAX. Load

7A

7A

7A

0.3A

2.0A

 

Low Load

0.30A

1.0A

0.50A

0.01A

0.1A

 

Peak Load

10A

10A

14A

 

 

Regulation

±5%

±5%

±5%

±10%

±5%

Ripple

80mV

80mV

150mV

150mV

80mV

Noise

120mV

120mV

240mV

240mV

100mV

 

 

 

 

 

 

 

 

 

 

 

 

 

                                                         

Note:

 

⑴ The continuous max. DC output power shall not exceed 150W, +3.3V and +5V combined continuous output power 60W max.

⑵ +12V peak surge current 12sec. Max.

⑶ A 0.1uF and 10uF tantalum capacitors should be put across output terminals during ripple & noise test. The oscilloscope bandwidth is set at 20 MHz and co-axial probe will be used to measure it.

⑷ The cross-load regulation in defined in the matrix below.(Unit: A)

Item

Load

+3.3V

+5V

+12V

-12V

+5Vsb

1

High

2.0A

4.0A

2.0A

0.5A

0.8A

Low

0.30A

1.0A

0.50A

0A

0.05A

2

High

10A

2A

2A

0.3A

2.0A

Low

2.8A

4.4A

2.0A

0.1A

0.1A

 

 

1.3 Protection

 

If the power supply is latch into shutdown stage (when OPP,OVP or short protection is working), the power supply shall return to normal operation only after the fault has been removed and remote signal must reset for a minimum of 1 seconds. Then, it will turn on again. The +5Vsb must be capable of being shorted indefinitely, but when the short is removed, the power supply shall recover automatically or by cycling the PS-ON#.

 

1.3.1 OVER POWER PROTECTION

 

The power supply will be shutdown and latch off when total power over 110%~150% of rated DC output.

Notes: 5VSB will be auto-recovery when the fault removed.

 

1.3.2 OVER VOLTAGE PROTECTION

 

Output

Min

Nom.

Max.

Unit

+12VDC

13.4

14.5

15.6

Volts

+5VDC

5.74

6.3

7.0

Volts

+3.3VDC

3.7

4.0

4.3

Volts

 

 

1.3.3 SHORT CIRCUIT PROTECTION

All output to GND.

 

1.4 Time Sequence

 

1.4.1 Power On Time

500ms Max. at 100% Load

1.4.2 PWR_OK (Power Good)

100mS-500mS at 100% Load

1.4.3 Power Good Delay Time

1 mS Min. at 70% Load

1.4.4 Hold-up Time

14 mS Min. at 70% Load

 

 

1.5 Remote On/Off Control

 

PS-ON# is active-low, TTL-compatible signal that allows a motherboard to remotely control the power supply in conjunction with features such as soft on/off, wake-on-LAN, or wake-on-modem. When PS-ON# is pulled to TTL low, the power supply should turn on the four main DC output rails:+12VDC,+5VDC,+3.3VDC,-12VDC. When PS_ON# is pulled to TTL high or open circuited, the DC output rails should not deliver current and should be held at zero potential with respect to ground. PS_ON# has no effect on the +5VSB output, which is always enabled whenever the AC power is present.

 

 

Min.

Max.

Vil, Input Low Voltage

0.0V

0.8V

Iil, Input Low Current, Vin=0.4V

 

-1.6 mA

Vih, input     High Voltage,   Iin=-200Ua

2.0V

 

Vih, Open Circuit, Iin=0

 

5.25V

 

 

1.6 +5Vsb

 

+5VSB is a “standby” supply output that is active whenever the AC power is present. It provides a power source for circuits that must remain operational when the four main DC output rails are in a disabled state. Example uses include soft power control, wake-on-LAN, wake-on-modem, intrusion detection, or suspend stage activities. +5VSB is required for the implementation of PS_ON#.

The +5VSB output should be capable of delivering a minimum of 2000 mA at +5V +/- 5% to external circuits. Overcurrent protection is required on the +5VSB output regardless of the output current ration. This ensures the power supply will not be damaged if external circuits draw more current than the supply can provide.

 

 

1.7 HI-POT

1000VAC 3S 10mA Min

Input-GND:

 

 

1.8 Earth Continuous test

100mΩ Max at 25A

 

 

1.9 Leakage Current Each Line To GND

3.5 mA Max at 264VAC 50HZ

 

 

2.0 Environment

 

 

2.1 Temperature

Operating ambient

+10℃ - +50℃

(At full load, with a maximum rate of change of 5℃/10minutes,but no more than 10℃/hr.)

Non operating ambient

-40℃ to +70℃

(Maximum rate of change of 20℃/hr.)

 

 

2.2 Humidity

Operating To 85% relative humidity (noncondensing)

Nonoperating To 95% relative humidity (noncondensing)

Note:95% RH is achieved with a dry bulb temperature of 55℃ and a wet bulb temperature of 54℃.

 

 

2.3 Altitude

Operating To 10000ft

Nonoperating To 50000ft

 

 

2.4 Mechanical Shock

Nonoperating 50g, trapezoidal input; velocity change 170 in/s

Three drops on each of six faces are applied to each sample.

 

 

3.0 CHASSIS MECHANICAL DIMENSION AND WIRE LENGTH

 

200 - 260V AC 200W Switching Mode Power Supply CE RoHS Approved 0

 

Contact Details
Shenzhen Power Adapter Co.,Ltd.

Contact Person: Mr. li

Tel: 56966398

Fax: 86-20-5696-5696

Send your inquiry directly to us (0 / 3000)

Contact

Address: 4th Floor, No. 174, Binjiang Xi Road, Haizhu District, shenzhen,Guangdong,China(Mainland)

Factory Address:4th Floor, No. 174, Binjiang Xi Road, Haizhu District, shenzhen,Guangdong,China(Mainland)